12kv Ime ụlọ High Voltage Ac Earthing Switch
Isi nka nka
Ihe | Nkeji | Data | ||
Egosiri voltaji | kV | 12 | ||
Obere oge na-anagide ugbu a | kA | 31.5 | ||
Edere ogologo oge okirikiri | s | 4 | ||
Enyere ọkwa mkpirisi okirikiri nso nso ugbu a | kA | 80 | ||
Ogo kacha elu na-anagide ugbu a | kA | 80 | ||
Enyere ọkwa mkpuchi mkpuchi | Enyere ike obere oge | kV | Agba ruo n'ụwa/n'etiti nkeji oge | 42 |
Obere ọkụ ọkụ na-anagide voltaji | 75 | |||
Mechanical ntachi obi | Oge | 2000 |
Nkọwa nka nka
GPJN15-12/31.5 Ihe ngbanwe ụwa na nha nrụnye
GPJN15A-12/31.5 okirikiri ngbanwe ụwa na nha nrụnye
24kv Indoor High Voltage AC Earthing Switch
Isi oru data
Ihe | Nkeji | Data | ||
Egosiri voltaji | kV | 24 | ||
Obere oge na-anagide ugbu a | kA | 31.5 | ||
Enyere ọkwa mkpirisi okirikiri nso nso ugbu a | kA | 80 | ||
Ogo kacha elu na-anagide ugbu a | kA | 80 | ||
Edere ogologo oge okirikiri | s | 4 | ||
Enyere ọkwa mkpuchi mkpuchi | 1min ugboro ike na-eguzogide voltaji | kV | Agba ruo n'ụwa/n'etiti nkeji oge | 65 |
Ọkụ ọkụ na-eguzogide voltaji | 125 | |||
Mechanical ntachi obi | ugboro | 2000 |
GPJN15-24/31.5 Ihe ngbanwe ụwa na nha nrụnye
40.5kv ime ụlọ elu voltaji AC Earthing mgba ọkụ
Isi oru data
Ihe | Nkeji | Data | ||
Egosiri voltaji | kV | 36/ 38/40.5 | ||
Obere oge na-eguzogide ugbu a(4s) | kA | 31.5 | ||
Enyere ọkwa mkpirisi okirikiri nso nso ugbu a | kA | 80 | ||
Ogo kacha elu na-anagide ugbu a | kA | 80 | ||
Ogologo usoro | mm | 300, 350, 400 | ||
Enyere ọkwa mkpuchi mkpuchi | (1min) Ugboro ike na-anagide voltaji | kV | Agba ruo n'ụwa/n'etiti nkeji oge | 95 |
Ọkụ ọkụ na-eguzogide voltaji | 185 |
Nkọwapụta na nha nrụnye
GPJN15-12(24)(40.5)kV moto ala ala mgba ọkụ
GPJN15-12 (24)/D31.5, GPJN15-12/D40, 50, GPJN15-40.5/D31.5 usoro ime ụlọ elu voltaji motorized earthing mgba ọkụ (obere dị ka: moto earthing mgba ọkụ) e mere maka ọgụgụ isi switchgear chọrọ nke ihe ndị ahụ. usoro eletriki.Ọ bụ uwe maka 3 ~ 40.5KV, 3 frasi, AC 50 (60) Hz ike usoro na ụdị nke elu voltaji switchgears.Ọ na-adabara maka nnukwu voltaji switchgear ndokwa dị ka earthing nchebe mgbe mmezi.
Arụmọrụ nke ngwaahịa na-ezute GB1985-2004 High Voltage AC Disconnector na Earthing Switch na ihe achọrọ nke ọkọlọtọ yana IEC62271-102:2002.
Earthing mgba ọkụ Ọdịdị dị mfe na kọmpat, ìhè arọ, mgbanwe ọrụ, mfe echichi, ike thermal kwụsie ike, na a pụrụ ịdabere na electric ọrụ, na-na mbụ interlocks na-ejide rabbits switchgear yinye mgbe nile, a mba patent.
Nlereanya Ngwaahịa na Pụtara ya
Ntọala ntọala
Ụdị ngwaahịa | GPJN15 | ||||
Egosiri voltaji arụ ọrụ | 12kV | 24kV | 40.5kV | ||
Obere oge na-eguzogide ugbu a (4S) | 31.5kA | 40kA | 50kA | 31.5kA | |
Ogo kacha elu na-anagide ugbu a | 80kA | 100kA | 125kA | 80kA | |
Enyere ọkwa mkpirisi okirikiri nso nso ugbu a | 80kA | 100kA | 125kA | 80kA | |
Ọkwa mkpuchi: | Isi sekit na-anagide voltaji (1min) | 42kV | 65kV | 95kV | |
Obere ọkụ ọkụ na-anagide voltaji | 75kV | 125 kV | 185kV | ||
N'ofe anya ka emeghere ọ bụghị ihe na-erughị | 125mm | 200 mm | 300mm | ||
Voltaji njikwa | AC220V | DC220V | DC110V |