12/24/40.5kV shutter Assembly na interlocking
Mgbakọ Shutter 5GP.320.010 Eserese nwụnye
(800mm obosara nke etinyere n'etiti mgba ọkụ)
Mgbakọ shutter 5GP.320.010 Ndepụta nhazi
Mba. | Aha | Ihe osise mba. | Qty.(pc/set) |
1 | Ihe nkwado aka nri | 8GP.123.011 | 1 |
2 | Efere njikọ aka nri | 5GP.235.011 | 1 |
3 | Na-egosi mkpado | 8GP.866.014 | 1 |
4 | Njikọ aka ekpe | 5GP.235.010 | 1 |
5 | Ihe nkwado aka ekpe | 8GP.123.010 | 1 |
6 | Njikọ ịgbado ọkụ | 5GP.174.016.1 (Maka VD4) | 2 |
5GP.174.016.2 (Maka GPVN) | |||
5GP.174.016.3 (Maka VB2) | |||
7 | Ọnụ ụzọ mgbochi ala | 8GP.320.010 | 1 |
8 | Mgbochi mechiri 8 | DK-8 | 8 |
9 | Efere ihe nkwado | 8GP.123.013 | 3 |
Mba. | Aha | Ihe osise mba. | Qty.(pc/set) |
10 | Njikọ ịgbado ọkụ | 5GP.174.017.1 (Maka VD4, 40kA) | 2 |
5GP.174.017.2 (Maka VD4, 31.5kA) | |||
5GP.174.017.3 (Maka GPVN) | |||
5GP.174.017.4 (Maka VB2) | |||
11 | Na-egosi mkpado | 8GP.866.012 | 1 |
12 | Na-egosi mkpado | 8GP.866.013 | 2 |
13 | Efere ihe nkwado | 8GP.123.012 | 3 |
14 | Ihe mkpuchi elu | 8GP.320.011 | 1 |
15 | mkpanaka ndu | 8GP.234.011(Maka VD4, GPVN) | 2 |
8GP.234.011.1 (Maka VB2) | |||
16 | Nkwụsị aka uwe | 8GP.210.011 | 2 |
Ndepụta nhazi nkọwa nkọwa ndị ọzọ
Koodu | 5GP.320.010.1 | 5GP.320.010.2 | 5GP.320.010.3 | 5GP.320.010.4 | 5GP.320.010.5 |
Obosara kabinet | 650mm | 700mm | 840 mm | 900mm | 1000mm |
Ọnụ ụzọ ámá elu | 8GP.320.011.1 | 8GP.320.011.2 | 8GP.320.011.3 | 8GP.320.011.4 | 8GP.320.011.5 |
Ọnụ ụzọ ámá | 8GP.320.010.1 | 8GP.320.010.2 | 8GP.320.010.3 | 8GP.320.010.4 | 8GP.320.010.5 |
Mgbakọ mkpuchi 5GP.320.011
(1000mm obosara nke etiti etinyere switchgear)
Ngwaọrụ Shutter Mechanism 5GP.320.011 Ndepụta nhazi
(1000mm obosara nke etiti etinyere switchgear)
Mba. | Aha | Ihe osise mba. | Qty.(pc/set) |
1 | Ihe nkwado aka nri | 8GP.123.276 | 1 |
2 | Efere njikọ aka nri | 5GP.235.012 | 1 |
3 | Na-egosi mkpado | 8GP.866.014 | 1 |
4 | Efere njikọ aka ekpe | 5GP.235.013 | 1 |
5 | Ihe nkwado aka ekpe | 8GP.123.275 | 1 |
6 | Mgbakọ weld njikọ | 5GP.174.281 | 2 |
7 | Ihe mkpuchi ala | 8GP.320.273 | 1 |
8 | Mgbochi mechiri 10 | DK-10 | 8 |
Mba. | Aha | Ihe osise mba. | Qty.(pc/set) |
9 | Efere ihe nkwado | 8GP.123.278 | 3 |
10 | Njikọ ịgbado ọkụ njikọ | 5GP.174.282 | 2 |
11 | Na-egosi mkpado | 8GP.866.012 | 1 |
12 | Na-egosi mkpado | 8GP.866.013 | 2 |
13 | Efere ihe nkwado | 8GP.123.277 | 3 |
14 | Ihe mkpuchi elu | 8GP.320.274 | 1 |
15 | mkpanaka ndu | 8GP.234.272 | 2 |
16 | Nkwụsị aka uwe | 8GP.210.011 | 2 |
Ndepụta nhazi nkọwa nkọwa ndị ọzọ
Koodu | 5GP.320.011.1 | 5GP.320.011/JY | 5GP.320.011.2 | 5GP.320.011.3 |
Obosara kabinet | 800mm | 1000mm (ihe mkpuchi) | 1100mm | 1200mm |
Ọnụ ụzọ ámá elu | 8GP.320.274.1 | 5GP.320.275 | 8GP.320.274.2 | 8GP.320.274.3 |
Ọnụ ụzọ ámá | 8GP.320.273.1 | 5GP.320.275.1 | 8GP.320.273.2 | 8GP.320.273.3 |
Rịba ama: 5GP.320.275 bụ maka mkpuchi mkpuchi site na SMC efere n'etiti na njedebe abụọ site na efere ígwè, mgbakọ shutter ọzọ ma ọ bụrụ na ọ dị mkpa mkpuchi mkpuchi, biko kọwaa.
Ngwa mgba ọkụ na-arụ ọrụ n'ime ala (N'ihi na njikọ ogwe aka mbanye na-arụ ọrụ) 5GP.363.010.1 eserese mgbakọ
Ntuziaka nke Interlock Device
The interlock ngwaọrụ na-agbakwunyere agbara interlock na n'azụ ụzọ nke e mere na ndabere nke mbụ 5GP.363.010 earthing mgba ọkụ ọrụ usoro interlock ngwaọrụ.Ya bụ, mgbe earthing mgba ọkụ na-emechi na-emeghe n'azụ ụzọ (akara efere), mbụ interlock nwere ike na-arụ ọrụ earthing mgba ọkụ, ma a interlock enweghị ike.Ị ga-ebu ụzọ mechie ụzọ azụ (efere akara) iji rụọ ọrụ mgba ọkụ.
Ụkpụrụ na-arụ ọrụ nke interlock ngwaọrụ na-agbanwe na No. 24 mkpọchi uwe aka ihe gosiri na nri na kwukwara mmiri na ndabere nke mbụ 5GP .363.010.Mgbe ọnụ ụzọ azụ (efere akara) mepere, mkpuchi mkpuchi na-abanye n'ime oghere square nke kabinet (nha akwadoro 35X35), enweghị ike iji mgba ọkụ earthing.
Ngwa mgba ọkụ na-arụ ọrụ nke ala (maka ọrụ mbanye ogwe aka njikọ)
5GP.363.010.1 nhazi ndepụta.
Mba. | Aha | Ihe osise mba. | Qty.(pc/set) |
1 | Na-ebu | 8GP.263.011 | 1 |
2 | Ngalaba | 8GP.192.010 | 1 |
3 | Ngalaba | 8GP.192.011 | 1 |
4 | Axis aka uwe | 8GP.210.014.1 | 2 |
5 | Ngalaba | 8GP.151.041 | 1 |
6 | Axis aka uwe | 8GP.211.061 | 1 |
7 | Ngalaba | 8GP.151.039 | 1 |
8 | Axis aka uwe | 8GP.211.062 | 1 |
9 | M5 × 12 | GB70-85 | 1 |
10 | Ngalaba | 8GP.151.042 | 1 |
11 | Ngalaba | 8GP.151.043 | 1 |
12 | mkpanaka arụ ọrụ | 8GP.200.013.1 (Ogologo 1432 maka omimi kabinet 1500 omimi) | 1 |
8GP.200.013.2 (Ogologo 1590 maka omimi kabinet 1660) | 1 | ||
13 | Efere nkwado | 8GP.161.058 | 1 |
8GP.161.058.1 (Maka nhọrọ) | 1 |
Mba. | Aha | Ihe osise mba. | Qty.(pc/set) |
14 | Mkpuchi | 8GP.017.011.1 | 1 |
15 | Bracket | 5GP.043.022 | 1 |
16 | Efere nkwado | 8GP.161.059 | 1 |
17 | Ihe mmịfe | 8GP.143.010 | 2 |
18 | Axis aka uwe | 8GP.211.058 | 1 |
19 | Nkwụsị aka uwe | 8GP.211.057 | 3 |
20 | ntọala nkwado | 8GP.043.019 | 1 |
21 | Na-egosi nso | 8GP.866.010 | 1 |
22 | Mgbakọ mkpanaka njikọ | 5GP.233.030.1 | 1 |
5GP.233.030.3 (Maka nhọrọ) | 1 | ||
23 | Mepee na-egosi | 8GP.866.011 | 1 |
24 | Ihe mkpuchi mkpuchi | 8GP.211.201 | 1 |
25 | Efere nkwụnye eze | 8GP.151.044 | 1 |
26 | Axis aka uwe | 8GP.211.060 | 2 |
27 | Mkpado | 8GP.860.010 | 1 |
28 | Mmiri nrụgide | 8GP.282.201 | 1 |
29 | Ihe mkpuchi mkpuchi na-edozi Bolt | 8GP.920.002 | 1 |
Mara:
1. Mba 1 ~ 12 lee ibe gara aga.
2. Mba 22 Mgbakọ mkpara njikọ, ogwe aka njikọ nwere nha abụọ: Ebe etiti Cabinet 60mm na-ejikọta ọnụ.Ọ bụrụ na ọ dị mkpa 80mm etiti etiti biko lelee ibe 17 ntuziaka nzụkọ ogwe aka njikọ, wee kọwaa mgbe ị na-enye iwu.
Ngwa mgba ọkụ na-arụ ọrụ n'ime ala (maka ọrụ mbanye bevel) 5GP.577.1001
Ngwa mgba ọkụ na-arụ ọrụ n'ime ala (maka ọrụ mbanye bevel) 5GP.577.1001 ndepụta nhazi
Mba. | Aha | Ihe osise mba. | Qty.(pc/set) |
1 | Na-ebu | 8GP.263.011 | 1 |
2 | Efere efere | 8GP.151.084 | 2 |
3 | Axis aka uwe | 8GP.210.014.1 | 2 |
4 | Ngalaba | 8GP.151.041 | 1 |
5 | Axis aka uwe | 8GP.210.014.2 | 1 |
6 | Bolt M 5X12 | GB70-85 | 1 |
7 | Ngalaba | 8GP.151.042 | 1 |
8 | Ngalaba | 8GP.151.043 | 1 |
9 | Axis aka uwe | 8GP.210.014.3 | 1 |
Mba. | Aha | Ihe osise mba. | Qty.(pc/set) |
10 | Nkwụsị aka uwe | 8GP.210.322 | 1 |
11 | mkpanaka arụ ọrụ | 8GP.174.214 | 1 |
12 | Mkpuchi | 8GP.017.011.2 | 1 |
13 | ntọala nkwado | 5GP.043.022 | 1 |
14 | Ihe mmịfe | 8GP.143.010 | 2 |
15 | Efere nkwado | 8GP.161.059 | 1 |
16 | Efere nkwado | 8GP.161.058 | 1 |
17 | Efere nkwụnye eze | 8GP.151.044 | 1 |
18 | Mkpado | 8GP.860.010 | 1 |
Mara: 1. Usoro a chọrọ ka ejikọtara ya na ọnụ ụzọ ala, biko kọwaa mgbe ị na-enye iwu.