Sivacon 8PT Voltaji dị ala ewepụrụ MCC Switchgear
Okwu mmalite
Ngwa ụdị GPS1 bụ maka ndị na-agbaji Siemens nke akụrụngwa nkesa ike dị ala, nke nwere teknụzụ mgbawa sekit, teknụzụ edobere ugwu, teknụzụ imewe ewepụrụ na teknụzụ nkwụnye.Ọ nwere nchekwa, ntụkwasị obi, mgbanwe, nke a na-ejikarị eme ihe na ụlọ ọrụ ihe owuwu na mpaghara teknụzụ mmepụta ihe.
Ngwaahịa nwere njirimara ndị a:
● Ụdị nkesa nkesa voltaji dị ala-nwalere (TTA);
● Ụgbọ ala kwụ n'ahịrị ahaziri n'elu ihe ngbanwe;
● 3-Pole na 4-pole busbar usoro nke dị ugbu a ruo 7400A;
● Ọnụ ọgụgụ kacha elu na-eguzogide ugbu a 1pk nwere ike iru 375kA;
● Nnukwu omimi akụkụ nke akụrụngwa ngwaọrụ, kwesịrị ekwesị maka ntinye dị iche iche;
● Enwere ike kewaa akụkụ ngwaọrụ n'ime nkeji dị iche iche dị ka nhazi modulus;
● Enwere ike itinye ihe mgba ọkụ n'otu akụkụ, nwekwara ike ịlaghachi azụ azụ;
● Ahịrị na-abata nwere ike ịbụ site n'elu ma ọ bụ site na ala;
● Enwere ike ijikọ eriri ndị na-apụ apụ site n'ihu ma ọ bụ azụ nke kabinet.
Ngwa mgba ọkụ eletrik dị ala GPS1 nwere ngụkọta nke atụmatụ anọ: ihe nbibi chepụta, ihe edobere n'elu, imebe nkwụnye na imewe iwepụ.
Nhazi nhazi maka omume, ọkwa ụgbọ ala dị ugbu a nwere ike kewaa n'ime 3200A, 4000A, 7400A, eriri eriri USB n'akụkụ ma ọ bụ n'azụ, enwere ike ibufe ihe na-agbaji sekit site na njikọ njikọ, ọnọdụ ule na ọnọdụ dịpụrụ adịpụ.Naanị onye na-agbaji n'ọnọdụ dịpụrụ adịpụ, ọnụ ụzọ ahụ nwere ike imeghe, nke a na-eme ka nchekwa nke onwe onye kachasị.
Ihe owuwu kabinet a kapịrị ọnụ, nke na-eme sekit ndị na-enye nri na kabinet nwere ike ịbụ ngwakọta ọ bụla.Cabinet arụnyere ma ọ bụ tinye ụdị kpụrụ sekit sekit breakers(MCCB), fuse ụdị disconnectors, ma ọ bụ warara-ụdị disconnectors na fuse, ya nkesa busbar kacha nke gosiri ugbu a bụ 1400A;Klas nchebe nke nkesa busbar nke warara fuse kabinet bụ IP20B, na-eji ibe 3NJ6 fuse mgba ọkụ, ngwaọrụ nwere ike dochie na-enweghị ike ala dum kabinet.Kabinet akwụ ụgwọ ihe ike nwere ụdị kpagbu na nke na-abụghị kpagbu.
Nhazi drawer ọ bụla nwere njikọ ejikọrọ, ọnọdụ nnwale na ọnọdụ dịpụrụ adịpụ.Ndị na-ese ihe karịrị 125A nwere usoro nwere ike imeri drawer na-aga n'ihu na usoro esemokwu.Oke kacha nke drawer dị ugbu a nke 630A, drawer modulus bụ 100,150,200,300,400,500,600,700mm.
A na-eme ụdị nkwụnye ahụ ka ọ bụrụ ngwaọrụ arụnyere na slats, nkwụnye n'ime isi sekit na ihe nkwụnye inyeaka na slat, isi eriri sekit iji weghara wiring jikọọ ozugbo na ngwaọrụ ndị na-emepụta ihe.Nhazi a bụ ọnụ ahịa akụ na ụba karịa.
Iji meghari mkpa injinia dị ka ụkpụrụ ọkọlọtọ BS si dị, a na-eme usoro ụgbọ ala niile emebere 3S gosipụtara obere oge iji guzogide ule ugbu a.
Ọdịdị Frame na Mkpuchi
Akụkụ ndị na-ebu ibu nke kabinet mgba ọkụ skeleton, nke ejiri profaịlụ ígwè ejikọrọ na ibe ya, usoro ọkpụkpụ GPS1 ziri ezi ma kwụsie ike.Enwere ụdị ihe owuwu abụọ, ya bụ njikọ ịghasa ma ọ bụ welded.
● Profaịlụ nwere modul oghere oghere 25mm iji gboo mkpa nke ndọtị dị iche iche
● Ịtụgharị isi iyi pụrụ ịdabere na ya gbochie ịpụ n'ọnụ ụzọ n'amaghị ama ma ọ bụ na mberede
● Ụlọ elu nke nwere ngwaọrụ enyemaka nrụgide
Mkpuchi
Efere akwa
A na-agbanye efere ụlọ n'elu etiti ahụ, enwere ike ibuli elu ụlọ ahụ na-enweghị dismantling switchgear, IPX1 ma ọ bụ IPX2 ụdị mkpuchi mkpuchi ụlọ ga-ebuga dị ka ngwa.
Efere ala
Iji mechie SPS1 site na ala, nwere ike screwed ka framing plurality nke ígwè efere, ị nwere ike punch oghere n'ala maka threading na cables.N'ihi na elu larịị nke nchedo chọrọ, Mgbe holing ala efere na saịtị nwere ike iji mgbe akara nri maka igbochi.
Efere azụ na mgbidi akụkụ
GPS1switchgear azụ na akụkụ bụ nke na-abụghị chamfered flat steel efere na kposara mmasị na nkwado Ọdịdị.
Efere nkebi
Dị ka esịtidem nkewa nke dị iche iche ụdị, n'ihi na GPS1 switchgear kabinet echichi n'ahịrị, nkebi efere nakweere maka iche n'etiti ụdị nke nkewa.A na-agbanye Spacer n'èzí nke etiti aka ekpe.
Nkọwa ọkpụkpụ
Nlebanya ụdị edozibere yana atụmatụ
OFF1 na-eji kabinet na-arị elu teknụzụ na-arị elu, enwere ike itinye ya ndị na-agbaji sekit sekit (MCCB), fuse switch disconnectors.
Gbanyụọ1 sekit na-apụ apụ arụnyere site na nhazi nke akụkụ ngwaọrụ modular ma dị n'azụ nke eriri USB.
N'ihu Switchgear bụ ọnụ ụzọ ma ọ bụ efere.
Gbanyụọ2 nkesa kabinet nke nri sekit na-apụ apụ na-eji teknụzụ mgbago kwụ ọtọ nwere ike itinye ya n'ụdị sekit sekit (MCCB), fuse switch disconnectors.
Gbanyụọ ọkụ eletrik nke sekit feeder sekit na-agbanye n'efere rịgoro ma jikọọ na bọs nkesa kwụ ọtọ n'akụkụ na-abata.
Switchgear n'ihu nwere ọnụ ụzọ ọnụ ụzọ dị iche iche, ngalaba njikọ eriri USB dịkwa n'ihu.
Ihe mejupụtara kabinet nrụnye OFF3 bụ site na akụkụ ngwaọrụ modular yana eriri USB dị n'azụ kabinet.
OFF3 cable feeder circuits na-agbanye ọkụ eletrik n'elu efere a na-agbanye ma jikọọ na ụgbọ ala nkesa kwụ ọtọ nke akụkụ na-abata.
N'ihu Switchgear nwere ọnụ ụzọ ime ụlọ dị iche.
Gbanyụọ sekit ndị na-apụ apụ 4 na-edozi nrụnye nwere akụkụ ngwaọrụ modular yana akụkụ eriri dị n'ihu akụkụ nke kabinet.
Gbanyụọ 4 cable feeder sekit ọkụ eletrik na-agbanye n'elu efere a na-agbanye ma jikọọ na ụgbọ ala nkesa kwụ ọtọ n'akụkụ na-abata.
N'ihu Switchgear nwere ọnụ ụzọ ime ụlọ dị iche.
Nlebanya Ụdị-wepụta
Ejiri igwe eletriki eletriki na sekit feeder nke switchgear na-ewepu na ebe nchekwa na-agbanwe agbanwe nke na-enye ọrụ dị mma, site na imewe nke a na-ewepụ, na-eme ka ngbanwe na ngbanwe ngwa ngwa ma dị mfe, nke pụtara na n'oge ọrụ ahụ, enwere ike ịgbakwunye akụkụ modul ma dochie ma ọ bụ gbanwee.
Atụmatụ
Main sekit nwere ihe mgbochi mbughari (na-agbaji n'akụkụ na-abata na n'akụkụ ụzọ ọpụpụ) na sekit inyeaka (ihe ruru 40-pin + 1 njikọ ụgbọ ala) nke usoro kọntaktị.Usoro nchebe eji eme ihe n'ụzọ na-ezighị ezi na-egbochi mmegharị ma ọ bụrụ na kọntaktị na ibu ahụ.N'ọnọdụ ule, enwere ike ịhụ arụmọrụ nke akụkụ ndị a na-ewepụ na ọnọdụ nke ibu na-ezighị ezi (ọnọdụ oyi).N'ọnọdụ a, anyị kwesịrị ịnyefe voltaji njikwa site na kọntaktị inyeaka.Klas nchebe na ọnọdụ ule na ọnọdụ dịpụrụ adịpụ ruru IP30.